NY360

NY360

Maximum power: 240-360KW
Model Name (NC:Natural Cooling LC:Liquid Cooling): DC124010-NC DC224010-LC DC130010-NC DC230010-LC DC136010-NC DC236010-LC
Input Voltage: 400VAC±10%, 50/60Hz,3Phase+N+PE(Compatible IT systems)
Input Rating: 252kW 316kW 379kW
Send Inquiry
Description
Technical Parameters
  • Comply with the ISO15118/DIN70121 charging protocol standards.
  • Support OCPP1.6J version.
  • Main components are CE certified.
  • Support dynamic load balancing(DLB) Function.
  • 10.1inch LCD touch-screen and 21.5inch Advertising screen.
  • Support RFID and POS machine payment (OPT).
  • Support APP control.
  • Cable management system.

 

Officials

Commercial Center

Public Transport

 

Product Specifications

 

 

Product Information

Model Name

NC:Natural Cooling

LC:Liquid Cooling

DC124010-NC

DC224010-LC

DC130010-NC

DC230010-LC

DC136010-NC

DC236010-LC

Input Voltage

400VAC±10%, 50/60Hz,3Phase+N+PE(Compatible IT systems)

Input Rating

252kW

316kW

379kW

Input Current

384A

480A

576A

Output Voltage

150~1000VDC

Output Rating

240kW

300kW

360kW

Output Current(Natural

Cooling and Liquid Cooling)

300A+300A(MAX)

500A+500A(MAX)

300A+300A(MAX)

500A+500A(MAX)

300A+300A(MAX)

500A+500A(MAX)

Stand-by Power

<50W/Outlet

Charging Outlets

DC:Double Outlets( CCS2+CCS2)Bottom Inlet Wiring, Up Outlet Wiring

Efficiency

≥94.5%

Power Factor

≥0.99(Load:100%)

Protection

Over/Under Voltage Protection, Overload Protection, Current leakage Protection, Lightening Surge Protection,Over Temperature Protection,Communication Interference Interruption Protection and Reset.

Earth Leakage Protection

Type A 30mA

Special Protection

Anti-UV Protection

Measuring Accuracy

Class 1.0

User Interface

Connectivity

Ethernet, WI FI, 4G

User Authentification

APP or RFID Card,POS Machine(OPT)

User Interface

10.1 Inch LCD Touch Screen/21.5 Inch Advertising screen/Emergency Stop Button/LED Indicator

Platform Protocol

OCPP1.6J

Software Update

OCPP

General Characteristics

IP&IK

IP55/IK10(Screen IK08)

Operating Altitude

<2000m

Operating Temperature

-30°C~+50°C( Derating above 50℃)

Working Humidity

5%~95% Without Condensation

Cooling

Forced-air Cooling

Mounting

Floor Stand

Dimensions

H2090*W815*D790

Weight

600-800kg

Cable Length

≥5m

Shell Material

Sheet Metal

Certification and Standards

Charging Standard

IEC61851-1;IEC61851-21-2;IEC61851-23;IEC61851-24;

Communication Protocol Standards

ISO15118-1-2013 ISO15118-2-2014; ISO 15118-3:2015; DIN 70121-2014

 

Natural Cooling

Area

Rated

Power

Product Name

Product Model

Module

Qty.

DC

Plug A

Maximum

Power of

Plug A

DC

Plug B

Maximum

Power of

Plug B

RFID

Button

IT

System

POS

Machine

4G

Ethernet

WiFi

Four-stage

Machine

Cable

Management

System

EU

240kW

UFC240_EU_All In One

ADC002C2120

C2120-NC

8

CCS-2

120kW

CCS-2

120kW

300kW

UFC300_EU_All In One

ADC002C2150

C2150-NC

10

CCS-2

150kW

CCS-2

150kW

360kW

UFC360_EU_All In One

ADC002C2180

C2180-NC

12

CCS-2

180kW

CCS-2

180kW

 

Liquid Cooling

Area

Rated

Power

Product Name

Product Model

Module

Qty.

DC

Plug A

Maximum

Power of

Plug A

DC

Plug B

Maximum

Power of

Plug B

RFID

Button

IT

System

POS

Machine

4G

Ethernet

WiFi

Four-stage

Machine

Cable

Management

System

EU

240kW

UFC240_EU_All In One

ADC002C2120

C2120-LC

8

CCS-2

120kW

CCS-2

120kW

300kW

UFC300_EU_All In One

ADC002C2150

C2150-LC

10

CCS-2

150kW

CCS-2

150kW

360kW

UFC360_EU_All In One

ADC002C2180

C2180-LC

12

CCS-2

180kW

CCS-2

180kW

√ Standard   ○ Option   - None 

 

You Might Also Like
Send Message