Workplace AC EV Charging Stations for Commercial Parking Facilities
Workplace AC EV charging stations provide AC charging for employees, visitors, and corporate fleets during working hours. Configurable power ratings, mounting options, access controls, and network functions help commercial property owners and project integrators match charging infrastructure to site requirements.
Flexible Power Options: 7.2 kW, 11 kW, and 22 kW configurations for different electrical supplies and vehicle onboard charger capacities.
Installation Options: Wall-mounted or pedestal-mounted configurations for indoor and outdoor parking facilities, subject to site conditions.
Access and Connectivity: Plug-and-play, RFID, mobile app, and backend management options, depending on the selected configuration.
Market-Specific Connectors: Type 2, Type 1, or NACS configurations, selected according to the target market and vehicle requirements.
OEM/ODM Customization: Branding, cable length, mounting accessories, and selected software settings can be configured subject to technical feasibility and order requirements.
Product Range and Technical Specifications
Select the Charging Power for Your Site
7.2 kW AC Charger: A single-phase option for workplace parking where vehicles remain parked for several hours.
11 kW AC Charger: A three-phase option for sites with a compatible electrical supply and vehicles capable of accepting this charging rate.
22 kW AC Charger: A higher-output AC option for sites with sufficient electrical capacity and vehicles supporting up to 22 kW AC charging.
Technical Specifications
|
Parameter |
7.2 kW Model |
11 kW Model |
22 kW Model |
|
Rated Output Power |
7.2 kW nominal |
11 kW |
22 kW |
|
Electrical Configuration |
Single-phase |
Three-phase |
Three-phase |
|
Rated Input Voltage |
230 V AC |
400 V AC |
400 V AC |
|
Rated Current |
32 A nominal |
16 A per phase |
32 A per phase |
|
Frequency |
50/60 Hz, subject to model specification |
50/60 Hz, subject to model specification |
50/60 Hz, subject to model specification |
|
Connector Options |
Market-specific |
Market-specific |
Market-specific |
|
Cable / Socket |
5 m tethered cable or socket, subject to configuration |
5 m tethered cable or socket, subject to configuration |
5 m tethered cable or socket, subject to configuration |
|
Connectivity |
Ethernet, Wi-Fi, or 4G, depending on model |
Ethernet, Wi-Fi, or 4G, depending on model |
Ethernet, Wi-Fi, or 4G, depending on model |
|
User Authentication |
Plug-and-play, RFID, or app, depending on model |
Plug-and-play, RFID, or app, depending on model |
Plug-and-play, RFID, or app, depending on model |
|
Enclosure Protection |
IP55 / IK10, subject to model verification |
IP55 / IK10, subject to model verification |
IP55 / IK10, subject to model verification |
|
Operating Temperature |
−30°C to +50°C, subject to model verification |
−30°C to +50°C, subject to model verification |
−30°C to +50°C, subject to model verification |
|
Mounting |
Wall or pedestal |
Wall or pedestal |
Wall or pedestal |
Key Features and Applications
Designed for Workplace Charging Requirements
Daytime Charging: Suitable for workplace parking where vehicles remain connected for several hours. Actual energy delivered depends on charging duration, available site power, and vehicle onboard charger limits.
Electrical Protection: Protection functions may include overvoltage, undervoltage, overcurrent, short circuit, surge, grounding fault, and residual-current protection, depending on the selected model.
Indoor and Outdoor Installation: IP55-rated enclosure options and IK10 impact resistance are available on applicable configurations. Confirm the specific model ratings and installation conditions before deployment.
Typical Applications
Corporate Offices: Employee charging during working hours, with access control where required.
Business Parks: Shared charging infrastructure for multi-tenant properties.
Commercial Real Estate: Charging services for tenants, visitors, and parking facility users.
Corporate Fleets: AC charging for vehicles parked between shifts or during scheduled downtime.
Smart Charging and System Integration
Connectivity, Load Management, and Compatibility
OCPP Integration: OCPP 1.6J connectivity is available on compatible configurations. OCPP 2.0.1 support must be confirmed for the selected model and firmware. Verify interoperability with the intended charging management platform before deployment.
Dynamic Load Management: Static or dynamic load balancing may be available depending on the charger, controller, metering equipment, and software configuration. Confirm supported system architecture and the maximum number of coordinated charging points.
User Authentication: RFID, mobile app, and backend-based access control options are available on selected models. Confirm required authentication methods and platform integration before ordering.
Regional Compliance: CE, CB, UKCA, RoHS, and UL-related options depend on the target market, model, and applicable requirements. Certificates and test reports must be checked against the exact product configuration.
Manufacturing, Quality Control, and Customization
Quality Control Process
Incoming Inspection: Critical electrical components, relays, cables, and other specified parts are checked against purchasing and product requirements.
Assembly Verification: Inspection of terminal torque, internal wiring, component installation, and enclosure sealing according to the applicable production procedures.
End-of-Line Testing: Electrical safety and functional checks may include dielectric strength, insulation resistance, grounding continuity, and simulated charging operation, as applicable to the model.
Pre-Shipment Inspection: Verification of product labels, accessories, order configuration, and export packaging before shipment.
OEM/ODM Customization
Branding and Packaging: Custom logos, selected color schemes, and branded packaging, subject to order quantity and production requirements.
Hardware Configuration: Alternative cable lengths, socket options, mounting pedestals, and accessories, subject to model compatibility.
Software Configuration: Supported OCPP endpoint settings, RFID configuration, and localized user-interface options, subject to firmware capabilities.
Project Documentation: Model-specific technical specifications, available test reports, and applicable compliance documents can be provided for review.
Bulk Orders, Project Support, and RFQ
Request a Project-Specific Quotation
To help evaluate product compatibility and prepare a suitable commercial proposal, please provide the following information.
Destination Market: Country or region, including applicable electrical and regulatory requirements.
Application and Installation: Office parking, business park, fleet facility, indoor or outdoor installation, and wall or pedestal mounting.
Electrical Requirements: Required power rating, single-phase or three-phase supply, available current capacity, and site power limitations.
Connector Configuration: Type 2, Type 1, or NACS, subject to the selected model and target market.
Smart Charging Requirements: RFID, mobile app, OCPP version, backend platform, 4G connectivity, and dynamic load management.
Order Details: Estimated quantity, sample or pilot requirements, OEM/ODM needs, and target delivery schedule.
Compliance Requirements: Applicable certifications, technical documents, and testing requirements for the destination market.
FAQ
Q: How do we choose between 7.2 kW, 11 kW, and 22 kW models?
A: Selection depends on the available electrical supply, phase configuration, current capacity, vehicle onboard charger limits, and parking duration. Confirm site conditions and vehicle compatibility before selecting a model.
Q: Do the charging stations support OCPP?
A: Compatible configurations support OCPP 1.6J. OCPP 2.0.1 availability, firmware support, and compatibility with the intended backend platform should be confirmed before ordering.
Q: Can multiple chargers operate with limited site power?
A: Load management may distribute available power among multiple charging points, depending on the selected hardware and control system. Confirm whether external meters, CT sensors, controllers, or additional software are required.
Q: Can you provide certificates and test reports?
A: Available documentation depends on the exact model, destination market, and applicable requirements. Request the relevant certificates and test reports for review before placing a bulk order.
Q: What are the MOQ and lead time for OEM/ODM orders?
A: MOQ and lead time depend on the selected model, order quantity, branding, hardware changes, and software requirements. Provide your target quantity and configuration to obtain a project-specific quotation.

